Compute true root mean square (RMS) value of signal

您所在的位置:网站首页 simulink block error Compute true root mean square (RMS) value of signal

Compute true root mean square (RMS) value of signal

2024-07-13 02:42| 来源: 网络整理| 查看: 265

RMS

Compute true root mean square (RMS) value of signal

expand all in page

Libraries: Simscape / Electrical / Specialized Power Systems / Sensors and Measurements

Description

The RMS block computes the true root mean square (RMS) value of the input signal. The true RMS value of the input signal is calculated over a running average window of one cycle of the specified fundamental frequency:

RMS(f(t))=1T∫t−Ttf(t)2dt,

where f(t) is the input signal and T is 1/(fundamental frequency).

As this block uses a running average window, one cycle of simulation must complete before the output gives the correct value. For the first cycle of simulation, the output is held to this specified initial RMS value.

CharacteristicsSample TimeSpecified in the Sample Time parameter. Continuous if Sample Time = 0.Scalar ExpansionYes, of the parameters.DimensionalizedYes.Examples

expand all

Calculate True RMS Value for Signal with Harmonics and at Fundamental Frequency

The power_RMS_THD example shows two applications of the RMS Measurement block. One RMS block calculates the true RMS value of a signal with harmonics, and another RMS calculates the RMS value of the same signal at the fundamental frequency.

The model sample time is parameterized by the Ts variable set to a default value of 50e-6 s. Set Ts to 0 in the command window to simulate the model in continuous mode.

PortsInput

expand all

Port_1 — Input signal scalar | vector

The input signal for which the block computes the RMS value, specified as a scalar or vector.

Output

expand all

Port_1 — RMS of input signal scalar | vector

The RMS value of the input signal, returned as a scalar or vector.

Parameters

expand all

True RMS value — Compute true or fundamental RMS value on (default) | off

Select this check box to have the block compute the true RMS value of the input signal.

Clear this check box to have the block compute the fundamental value of the input signal divided by sqrt(2).

Fundamental frequency (Hz) — Fundamental frequency 60 (default) | positive scalar

Specify the fundamental frequency, in hertz, of the input signal.

Initial RMS value — Initial RMS value 120 (default) | nonnegative scalar

Specify the initial RMS value of the output signal.

Sample time — Sample time of block 0 (default) | nonnegative scalar

Specify the sample time of the block, in seconds. Set to 0 to implement a continuous block.

Extended CapabilitiesC/C++ Code Generation Generate C and C++ code using Simulink® Coder™.Version History

Introduced in R2013a